Latest News
SFE Anomaly: After passage through the SAA on 2014/299 ~01:35 EDOS observed corrupted MODIS data. The cause was traced to a formatter card that had become out of sync resulting in the corrupt data. Only MODIS data is processed by this card so no other instruments were affected. FOT successfully reset the card and returned data flow to nominal operation. Expect a data loss from 2014/299 01:35:00 – 18:47:00. Exact loss time still to be confirmed by FOT.
Terra MODIS Collection 6 Level 1B products will be reprocessed to correct for the long term drift observed in the reflectance trending of band 5. More details regarding the reprocessing schedule can be found here: http://ladsweb.nascom.nasa.gov/news/news080414.html
Also, information regarding this calibration change can be found here.
https://mcst.gsfc.nasa.gov/content/collection-6-information
The presentations from the MODIS Science Team Meeting, April-2014 are available at the following location: http://modis.gsfc.nasa.gov/sci_team/meetings/201404/
Terra experienced an anomaly for B36/D7 beginning on 2014109.1405. Unlike previous instances of this unknown electronics/formatter anomaly, the detector behavior has not returned to normal.After 2 weeks continually being in the anomaly state, the decision was made to change the QA flag for this detector from 'Noisy' to 'Inoperable'. All Band 36 detectors are currently flagged as Noisy.
This QA change will be in effect from the LUT versions 5.0.46.73 (Collection 5) and 6.1.14.26 (Collection 6)
May 4, 2014 marked the 12 year anniversary of Aqua launch. The MODIS instrument on-board the Aqua spacecraft has well surpassed its design lifetime, but continues to provide valuable datasets for studies of Earth's land, ocean and atmosphere systems.
Pagination
- Previous page
- Page 10
- Next page
MODIS Characterization Support Team
The MODIS Characterization Support Team (MCST) is dedicated to the production of a high quality MODIS calibration product. This product is a precursor to every geophysical science product. MCST works for the Science Team Leader and is responsible for developing and maintaining the calibration product (L1B algorithm).
Calibration
Collection 6 has been under development for a number of years. MCST, in consultation with representatives of the science disciplines, developed improvements to the calibration algorithms and methodolgies to handle known issues with the aging MODIS sensors. Summary talks of the proposed Collection 6 changes have been delivered at the MODIS science team meetings over the last few years.
L1B
Current L1B LUT Versions:
Terra C6: 6.1.26.85; Terra C6.1: 6.2.2.107; Aqua C6: 6.1.37.88; Aqua C6.1: 6.2.3.32