Title Date UTC Year of DOY DOY Command Load Notes MODIS Mission
BB WU/CD 2005 203 ATC MOD_OA26_BB_315K_A.2 Set blackbody temperature to 315K on the A Side Terra
BB WU/CD 2005 202 ATC MOD_OA26_BB_290K_A.2 Set blackbody temperature to 290K on the A Side Terra
BB WU/CD 2005 202 ATC MOD_OA26_BB_285K_A.2 Set blackbody temperature to 285K on the A Side Terra
BB WU/CD 2005 202 ATC MOD_OA26_BB_280K_A.2 Set blackbody temperature to 280K on the A Side Terra
BB WU/CD 2005 201 ATC MOD_OA26_BB_270K_A.2 Set blackbody temperature to 270K on the A Side Terra
BB WU/CD 2005 201 MCL MOD_BB_TEMP_SET_285K_B.2 BB Temp Set to 285K for CP B Coefficients Aqua
BB WU/CD 2005 200 MCL MOD_BB_DCYCLE_THIRD.1 Set blackbody heater duty cycle to THIRD Aqua
BB WU/CD 2005 200 MCL MOD_BB_TEMP_SET_270K_B.2 BB Temp Set to 270K for CP B Coefficients Aqua
BB WU/CD 2005 200 MCL MOD_BB_DCYCLE_FULL.1 Set blackbody heater duty cycle to FULL Aqua
BB WU/CD 2005 200 MCL MOD_BB_TEMP_SET_315K_B.2 BB Temp Set to 315K for CP B Coefficients Aqua
BB WU/CD 2005 200 MCL MOD_BB_TEMP_SET_290K_B.2 BB Temp Set to 290K for CP B Coefficients Aqua
BB WU/CD 2005 200 MCL MOD_BB_TEMP_SET_285K_B.2 BB Temp Set to 285K for CP B Coefficients Aqua
BB WU/CD 2005 199 MCL MOD_BB_TEMP_SET_280K_B.2 BB Temp Set to 280K for CP B Coefficients Aqua
BB WU/CD 2005 199 MCL MOD_BB_TEMP_SET_270K_B.2 BB Temp Set to 270K for CP B Coefficients Aqua
Nighttime Day Mode - 2005 198 MCL MOD_OA03_FR_NIGHT_RATE.2 OA-03: Formatter to Night Rate (nominal) Aqua
Nighttime Day Mode - 2005 197 MCL MOD_OA03_FR_DAY_RATE.1 OA-03: Formatter to Day Rate (10 min after groundtrack day) Aqua
Nighttime Day Mode - 2005 197 MCL MOD_OA03_FR_NIGHT_RATE.2 OA-03: Formatter to Night Rate (return to normal night rate) Aqua
Nighttime Day Mode - 2005 197 MCL MOD_OA03_FR_DAY_RATE.1 OA-03: Formatter to Day Rate (night ground track) Aqua
Nighttime Day Mode - 2005 197 MCL MOD_OA03_FR_NIGHT_RATE.2 OA-03: Formatter to Night Rate (10 min before groundtrack night) Aqua
Nighttime Day Mode - 2005 197 ATC MOD_OA03_DAY_RATE.2 OA-03: Formatter to Day Rate (10 min after groundtrack day) Terra
Nighttime Day Mode - 2005 197 ATC MOD_OA04_NIGHT_RATE.1 OA-04: Formatter to Night Rate (return to normal night rate) Terra
Nighttime Day Mode - 2005 197 MCL MOD_OA03_FR_DAY_RATE.1 20 minutes of DAY rate data over ground track night OA-03: Formatter to Day Rate Aqua
Nighttime Day Mode - 2005 197 ATC MOD_OA03_DAY_RATE.2 OA-03: Formatter to Day Rate (night ground track) Terra
Nighttime Day Mode - 2005 197 ATC MOD_OA04_NIGHT_RATE.1 OA-04: Formatter to Night Rate (10 min before groundtrack night) Terra
Nighttime Day Mode - 2005 197 ATC MOD_OA03_DAY_RATE.2 OA-03: Formatter to Day Rate 20 minutes of DAY rate during ground track night Terra
SD/SDSM - 2005 193 ATC MOD_OA16_SDSM_SCRN_NO_DOOR_A.4 OA-16: SD/SDSM screened side A, no door movement. Terra
SD/SDSM - 2005 192 MCL MOD_OA15_SDSM_OPEN.1 OA-15: SD/SDSM Open - B-Side Aqua
SD/SDSM - 2005 192 MCL MOD_OA16_SDSM_SCREEN.2 OA-16: SD/SDSM Screened - B-Side Aqua
Miscellaneous - 2005 189 MOD_MEM_PM_DUMP (’door_data’,12,0,0,1,21) Aqua
Miscellaneous - 2005 189 MOD_MEM_PM_DUMP (’motor_pos_when_hit’,12,0,0,1,1) Aqua
Miscellaneous - 2005 189 MOD_MEM_PM_DUMP (’motor_trigger_data’,60,0,0,1,2) Aqua
Miscellaneous - 2005 189 MOD_MEM_PM_DUMP (’motor_constants’,35,0,0,1,2) Aqua
SRCA Full Radiometric - 2005 183 ATC MOD_OA19_SRCA_FULL_RAD_A.6 OA-19: SRCA Full Radiometric Calibration. Data collection from 20:58:26-21:16:43. Terra
SRCA Setup - 2005 183 ATC MOD_SRCA_11_3_8_2_SETUP.1 SRCA setup activity using lamp #4 in lieu of lamp #2 Terra
Miscellaneous - 2005 181 MCL MOD_SRCA_OFF.1 Turns off the SRCA. Aqua
Miscellaneous - 2005 181 MCL MOD_SRCA_OFF.1 Turns off the SRCA. Aqua
Miscellaneous - 2005 181 MCL MOD_SRCA_OFF.1 Turns off the SRCA. Aqua
Miscellaneous - 2005 181 MCL MOD_SRCA_OFF.1 Turns off the SRCA. Aqua
Miscellaneous - 2005 181 MCL MOD_SRCA_OFF.1 Turns off the SRCA. Aqua
Miscellaneous - 2005 180 MCL MOD_SRCA_OFF.1 Turns off the SRCA. Aqua
Miscellaneous - 2005 180 MCL MOD_SRCA_OFF.1 Turns off the SRCA. Aqua
SRCA Full Radiometric - 2005 179 ATC MOD_OA19_SRCA_FULL_RAD_A.6 OA-19: SRCA Full Radiometric Calibration. Data collection from 23:10:29-23:29:44. Terra
SRCA Setup - 2005 179 ATC MOD_SRCA_NOMINAL_SETUP.4 SRCA setup activity using 10W lamps #1, 2, and 3, and 1W lamp #1 Terra
SD/SDSM - 2005 179 ATC MOD_OA16_SDSM_SCRN_NO_DOOR_A.4 OA-16: SD/SDSM screened side A, no door movement. Terra
Miscellaneous - 2005 179 MCL MOD_SRCA_OFF.1 Turns off the SRCA Aqua
Miscellaneous - 2005 179 MCL MOD_SRCA_OFF.1 Turns off the SRCA Aqua
Miscellaneous - 2005 179 Real-Time MOD_SRCA_PM_OFF Turns off the SRCA. Aqua
Miscellaneous - 2005 179 Real-Time MOD_SRCA_LAMPS(’OFF’) Turns the lamp off. Aqua
Miscellaneous - 2005 179 Real-Time MOD_SRCA_LAMPS(’W10’) Turns on the preselected 10W lamp #3. Aqua
Miscellaneous - 2005 179 Real-Time MOD_SRCA_SETUP (’B’, 11, 3, 2, 2, ’CURRENT’,’LOW’,’ENABLE’,’ON’) Sets lamp configuration, the SRCA to constant current mode, and turns on the SRCA. Aqua